甩尾測痛儀(疼痛甩尾測試儀甩尾儀Tail Flick Test Analgesia Meter Apparatus)(測試動物疼痛反應時間和動物對鎮痛藥物的疼痛反應極限使用簡便更多詳情敬請)
型號33型
疼痛甩尾測試儀用于測試動物疼痛反應時間和動物對鎮痛藥物的疼痛反應極限。實驗過程中檢測到動物尾部甩動后內置的計時器自動停止計時。
The Tail Flick Test apparatus meter measures latency and/or temperature threshold when detecting properties of narcotic and strong non-narcotic drugs on mice and rats. A built-in Timer is automatically stopped when the animals’ tail flicks out of the beam of light, test result will be displayed on readout for viewing.
An overhead halogen light source is in a constant “ON” (idle state). A pre-focused heat source supplies an area of 4X6mm stimulation to the tail. A built-in sensor in the tail groove detects the tail flick of the animal. The tail groove is a non-metallic material to avoid unnecessary conditioning of your animals; unlike other systems. If the animal does not flick their tail within the pre programmed cut-off time; the heat source shuts off automatically; avoiding tissue damage. Built-in timer displays the reaction time in 0.01 second increments. Control of system can be from either the front panel or supplied footswitch: Start, Stop and Reset of tests.
疼痛甩尾測試儀主要特點
? 實時尾部溫度/觸發可選
? 觸發溫度設置功能
? 精確數字控制時間精確度為0.01秒
? 自動切斷保護功能
? 光束強度可調節步進量1%
? 自動檢測活動反應
? 強制取消定時器功能
? 數字顯示功能
? 標準計算機打印口輸出
? RS-232輸出
相關文獻
T Schneider, A Roman, A Basta-Kaim, M Kubera… - …, 2008 - Elsevier
… adverse developmental consequences produced by early brain injuries, especially in animal
models of human … valproic acid have not been studied in the presented animal model of autism …
withdrawal test carried out using an Analgesia Meter apparatus (Mod 33, IITC, INC, USA …
R Karlsten, C Post, I Hide, JW Daly - Neuroscience letters, 1991 - Elsevier
… The animals were used only once. Testing of tail flick was performed using an IITC Inc. Model
33 Analgesiameter, with the light focused on the tip of the tail [3]. The intensity of the beam was
adjusted to give a reaction time of 3-4 s before the it injection of the drug solutions …
T Schneider, R Przew?ocki - Neuropsychopharmacology, 2005 -
… The thermal paw withdrawal test was carried out using an Analgesia Meter apparatus (Mod 33,
IITC, Inc., USA) … aberrations described in this paper appear before puberty, which could distinguish the VPA rat model of autism from other animal models of psychiatric …
J Jurcovicova, M Stancikova, K Svik… - Clinical and …, 2001 - clinexprheumatol.org
… They had free access to food. In group four AA was induced and the animals received 60%
of the food consumed by the arthritic rats (group 3) on the previous day … The pain threshold
was measured using the tail flick analgesia meter (Model 33 IITC Inc …
Y Yajima, M Narita, M Narita, N Matsumoto, T Suzuki - Brain research, 2002 - Elsevier
… each of the hind paws of mice was tested individually using a thermal stimulus apparatus (model
33 Analgesia Meter; IITC Inc./Life Science … An aliquot of tissue sample was diluted with an equal volume of electrophoresis sample buffer (Protein Gel Loading Dye-2x …
M Nishiyori, H Ueda - Molecular pain, 2008 -
… 10 μg in the neuropathic pain model, which is consistent with the previous study that … the ICS model is a promising candidate for experimental FMS or generalized pain syndrome models … thermal paw withdrawal test was carried out using a thermal stimulus (Model 33 Tail Flick …
M Kalinichev, KW Easterling, SG Holtzman - Psychopharmacology, 2001 - Springer
… an organism's responsiveness to stress has been exten- sively investigated in several rodent
models … Previous findings by Kehoe and Blass (1986) provide indirect evidence indicating that
maternal … a light source was focused on the lower third of the tail (Model 33, Tail Flick …
K Starowicz, SA Mousa, I Obara, A Chocyk… - Pharmacological …, 2009 - Elsevier
… PWL) in response to noxious thermal stimuli using an Analgesia Meter (mod 33, IITC INC., Landing, NJ … The initial phase of the CCI model of neuropathic pain involves inflammation around the nerve …restricted to the dorsal horns of the spinal cord, similar to previous studies [26 …
AR Gintzler, BR Komisaruk - Brain research, 1991 - Elsevier
… a lamp mounted 8 cm above the tail and was maintained until a response was elicited or 10 s
had elapsed (IITC Inc., Model 33, Landing, NJ) … Since in a previous study, there was no correlation between the magnitude of increase in TFL produced by vaginal stimulation and the …
YZ Gao, SY Guo, QZ Yin, T Hisamitsu… - The American journal of …, 2007 - World Scientific
… Previous studies have demonstrated that electroacupuncture (EA) at ST36 acupoint could produce profound analgesia … recording the tail flick latency (TFL) induced by radiant heat using Model 33 Tail Flick … Briefly, 750 ng of fast recovery sample cRNA were mixed with 750 ng of …
I Pekarkova, S Parara, V Holecek, P Stopka, L Trefil… - Physiol Res, 2001 - med.cas.cz
… It was found in our previous research in the field of pain that after repeated painful … The tail-flick test (TF) (Tail Flick Analgesia Meter Model 33, IITC Inc., Life Science Instruments, USA) measures the … Sample preparation On the last day of the experiment (the 5th day), after all the …
K Niikura, M Narita, M Narita, A Nakamura, D Okutsu… - Neuroscience …, 2008 - Elsevier
… paws of rats were tested individually using a thermal stimulus apparatus (model 33 Analgesia
meter … In the present study, sample preparation was performed 10 days after partial sciatic … 2B).
Consistent with many previous studies which have characterized afferent projections to …
HN Kariuki, TI Kanui, A Yenesew, NB Pa… - 2012 -
… Antinocieptive activity of Toddalia asiatica (L) Lam. in models of central and peripheral pain … Tail flick test A radiant heat tail-flick IITC Inc. Model 33 analgesiometer was used to measure response latencies according to the method described previously (Corrêa et al., 1996) …
3007536035
*您想獲取產品的資料:
個人信息: