鼠抓力測量儀

參考價面議
具體成交價以合同協(xié)議為準(zhǔn)

該廠商其他產(chǎn)品

我也要出現(xiàn)在這里

鼠抓力測量儀

詳細(xì)信息 在線詢價

詳細(xì)介紹

鼠抓力測量儀(大小鼠抓力測量儀鼠抓力測量Grip Strength Test Meter for Mice and Rats可用于小鼠或大鼠系統(tǒng)測試的使大鼠或小鼠釋放的抓力設(shè)計(jì)科學(xué)使用方便更多詳情敬請)

 

可用于小鼠或大鼠系統(tǒng)測試的使大鼠或小鼠釋放的抓力。常用于藥物、毒物、肌肉松弛藥、衰老、神經(jīng)損傷對肌力的影響。將大鼠或小鼠置于有機(jī)玻璃平臺上在抓力吊架前面。嚙齒動物會本能地抓取任何東西以嘗試去停止這種被動的反向運(yùn)動這將會持續(xù)抓吊臺直到牽力克服了抓力為止。動物失去其抓力后力峰值前級放大器會自動地儲存峰值的抓力并顯示在液晶板上。

 

傳感器結(jié)構(gòu)是T形或吊架形杠桿而且高度可調(diào)。杠桿適應(yīng)連接于峰值放大器上的測力傳感器。小鼠用單元與大鼠用相似只不過抓力吊架尺寸、測力傳感器對抓力測量的調(diào)節(jié)度不一致。     

 

The system is used to to assess muscle hyperalgesia. The IITC Life Science instrument measures the forelimb grip force using a digital force transducer.The transducer in the Grip Strength Meter is connected to a wire mesh grid connected to an anodized base plate. The animal is held by its tail and is gently passed over the mesh until it grasps the grid with its front paws.


大小鼠抓力測量儀的主要特點(diǎn)

 

拉力傳感器大力度值≥1500g 

大力可允許超過數(shù)值≥150g

讀數(shù)精度為0.1g

配備有基座、金屬套桿和傳感器Hub

配大小鼠網(wǎng)格和T形桿

陽極電鍍處理的面板并配備有固定吸盤

配備36g砝碼校準(zhǔn)模塊

數(shù)據(jù)采集器自帶電源可供數(shù)據(jù)采集器時間≥250小時

帶Clear清零鍵使用方便


系統(tǒng)組成

 

? 黑紗有機(jī)玻璃底座*包括有直立的單臂控制頭 

? 抓力桿(也可以提供一個抓力吊架) 

? 可調(diào)整高度的測力傳感器, 提供連接電纜連接到峰值放大器上的接頭

? 用于小鼠或大鼠的吊架

? 峰值放大器

? 用于大鼠或小鼠的T形杠桿,

? 直徑為10mm的有機(jī)玻璃盤

? 數(shù)字顯示器

? 夾鉗桌腿

? 電源線, 2根115V或230V的保險絲

? 安裝手冊



相關(guān)文獻(xiàn)

The monosodium iodoacetate model of osteoarthritis pain in the rat

CL Marker, JD Pomonis - Pain Research, 2012 - Springer

... 1. These instructions assume the use of a grip strength meter (IITC Life Science) that has been
adapted with a piece of plexiglass to ... the animal by the tail parallel to the mesh until both hind
paws are no longer gripping the mesh ... 9. Record the grip strength from the device display ...

 

 

Death receptor 6 (DR6) antagonist antibody is neuroprotective in the mouse SOD1G93A model of amyotrophic lateral sclerosis

G Huang, X Lee, Y Bian, Z Shao, G Sheng- Cell death & , 2013 -

... Toluidine blue staining of sciatic nerve to determine myelinated axons were described previously.
59. Grip strength. Grip strength was assessed using a grip strength meter (IITC Life Science,
Woodland Hills, CA, USA). ... For hindlimb strength, a T-bar grip was used. ...

 

 

Antinociceptive effect of d-Lys< sup> 2, Dab< sup> 4< i> N-(ureidoethyl) amide, a new cyclic 1-4 dermorphin/deltorphin analog

B Antkowiak, M Paluch, M Ciechanowska- Pharmacological , 2014 - Elsevier

... Grip strength test. The grip strength of forelimbs in mice was assayed using a meter
with a digital force transducer connected to a wire mesh grid (IITC Life Science, USA).
An animal was held by the base of its tail and gently passed ...


 

    

    

    

         

    

    

    

    