女人被暴躁C到高潮容易怀孕吗_国产成人精品一区二区三区视频_国产欧美日韩_德国FREE性VIDEO极品


免費注冊快速求購


分享
舉報 評價

乳酸.*.乙醇生物傳感器

參考價面議
具體成交價以合同協議為準

該廠商其他產品

我也要出現在這里

生物傳感器用于實時監測動物腦內神經化學物質的濃度變化。根據檢測物質不同,可用于*(Glutamate),葡萄糖(

詳細信息 在線詢價

詳細介紹

生物傳感器用于實時監測動物腦內神經化學物質的濃度變化。根據檢測物質不同可用于*(Glutamate)葡萄糖(glucose,乳酸( lactate and 乙醇(ethanol。配合數據采集器和軟件用于可用于記錄清醒活動狀態下動物中樞神經系統神經化學物質的濃度變化。通常用于行為學和生理活動研究是藥物篩選和神經藥理學研究的理想工具。

 

Biosensors monitor real-time changes in neurochemical concentrations. With Pinnacle's turn-key electronic and software systems, users can record and analyze second-by-second concentration changes (not basal level) of CNS neurochemicals in freely moving animals . Biosensors are commonly used for in vivo monitoring during behavioral and physiological activities. They are also ideal for drug screening and investigating the neuropharmacological effects of different compounds. 

 

BIOSENSOR TYPES

Pinnacle offers glutamate,glucose,lactateand ethanol sensors.
All sensors sold by Pinnacle are for non-human use only.

 

In Vivo Lifetime

Limit of Detection

GLUTAMATE

36 hours

0.05 - 0.1 uM

GLUCOSE

96+ hours

2 - 5 uM

CGMS GLUCOSE

17+ days

25 - 50 uM

LACTATE

96+ hours

5 - 10 uM

ETHANOL

6 - 8 hours

0.1 - 0.5 uM

 

BIOSENSOR DIAGRAM

Pinnacle sensors function by the enzyme-mediated processing of the analyte of interest. This results in the production of hydrogen peroxide that is then detected by oxidation at a Pt-Ir electrode. Electroactive interferents present in the brain are excluded via a passive selective membrane and through active removal when necessary. 

 

CARBON FIBER SENSORS

CARBON FIBER SENSORS (CFSs) are used in conjunction with Pinnacle’s tethered and wireless potentiostats to measure the presence of total genic amines in the brain using fixed potential amperometry (FPA). They are also used with fast scan cyclic voltammetry (FSCV) systems. All Pinnacle CFSs require an Ag/AgCl reference electrode (7065). The sensors are 34 µm in diameter and 0.5 mm in length.

 

GUIDE CANNULAS

Pinnacle recommends the use of a guide cannula system for optimal results when implanting and recording from sensors in the brain of a freely moving animal. Biosensors are compatible with several guide cannula types. Single-barrel, tri-barrel, and BASi cannluas are available for rats; BASi cannulas are available for mice. Sensors with no cannulas are also available for purchase. 

 

BIOSENSOR CALIBRATION
In order to relate the current changes measured by a sensor to actual changes in analyte concentration, it is necessary to calibrate the sensor at the conclusion of an experiment. The process also confirms the integrity and selectivity of the sensors. Pinnacle offers a number of in vitro calibration systems that allow the simultaneous calibration of four to eight sensors. Select the calibration kit that matches the hardware system and cannula type used in your experimental setup.

 

CALIBRATION KITS

Product

Kit #

Tethered mouse in vitro calibration kit

                  7000-K1-T           

Tethered rat in vitro calibration kit

              7000-K2-T-BAS  

Wireless rat in vitro calibration kit (BASi cannulas)



    

    

    

         

    

    

    

    



同類產品推薦


提示

×

*您想獲取產品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息: