女人被暴躁C到高潮容易怀孕吗_国产成人精品一区二区三区视频_国产欧美日韩_德国FREE性VIDEO极品


免費注冊快速求購


分享
舉報 評價

淋雨試驗箱

參考價面議
具體成交價以合同協議為準

該廠商其他產品

我也要出現在這里

ConfiguredforyourspecifictestsGrandemakesrainandspraytestingeasierbyofferingastandardchambercapableofpublishedandOEMproprietarytestmethods

詳細信息 在線詢價

Configured for your specific tests

Grande makes rain and spray testing easier by offering a standard chamber capable of published and OEM proprietary test methods.

The standardized design can be configured for the rain/spray tests you need, eliminating the guesswork in buying a chamber. The system is based on the specification requirements, and can also accomplish individual automaker’s tests, as well as electrical-enclosure tests.


Our Design

Grande's modular design allows you to add on additional features, depending on the number and type of tests required. One possible choice is to integrate the spray system with a regular temperature and humidity chamber to save money and floor space, while also creating an opportunity to simulate actual operating conditions your product may experience.

Our system uses multiple control solenoids to vary the water's spray volume/pressure. A holding tank prepares the water to the desired temperature, if required. A pump ensures the water is delivered in the proper pressure range. The water is fed to a motorized manifold that rotates the spray arms. Each spray arm has an adjustable valve to allow finer control of the spray.


Testing capabilities

The specification is modeled after and doesn’t differ greatly. Details about the nozzle types and the rotating nature of the spray arms and product table are also included in the requirements. Additionally, drip and car wash tests are also specified.


Heavy splash/er

· S1 Spray room temperature water with 40 nozzles at 14.2 psi (1 kgf/cm2) for 30 minutes. The flow rate of the water shall be 6.5 gallons/min. (24.5 L/m).

· S2 Spray room temperature water with 40 nozzles at 42.7 psi (3 kgf/cm2) for 60 minutes. The flow rate of the water shall be 10.3 gallons/min. (39.2 L/m).


Light spray/rain

· R1 Spray room temperature water with two nozzles at 4.3 psi (0.3 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.8 gallons/min. (3.2 L/m).

· R2 Spray room temperature water with two nozzles at 1.4 psi (0.1 kgf/cm2) for 10 minutes. The flow rate of the water shall be 0.5 gallons/min. (1.9 L/m).


Examples of OEM automotive manufacturers' requirements

· Heat the sample to a temperature above boiling, then spray with cold water for about two minutes. Repeat cycle.

· Heat the sample to boiling temperature, then spray with room temperature water for about fifteen minutes. Repeat cycle.

· Simulate a car wash by using high pressure spray.


Features

· Rotating rain and spray nozzles designed to JIS specifications

· Speed control for the rotating spray nozzles

· Stationary product shelf - A rotating shelf is optional: see options

· Water pressure regulators, gauges and flow meters

· Special high-volume floor drain system to rapidly drain water out of the chamber

· Interior chamber size is the smallest possible area using the JIS specified nozzles


Applicable Test Methods

· JSA JIS (Japanese Industrial Standard) D 0203 "Method of Moisture, Rain and Spray Test for Automobile Parts"

· SAE (Society of Automotive Engineers) J2245 "Recommended Practice for Splash and Spray Evaluation"

· SAE J575 "Test Methods and Equipment for Lighting Devices and Components"

"The cabinet shall be equipped with a nozzle(s) which provides a solid cone water spray of sufficient angle to completely cover the sample device. The centerline of the nozzle(s) shall be directed downward at an angle of 45 degrees to the vertical axis of a rotating test platform... The device shall be rotated about its vertical axis at a rate of 4.0 ± 0.5 rpm... The water spray test shall continue for 12 hours." ref: SAE J575.


Optional/additional test capabilities:

· Temperature/humidity controlled rain chamber: Includes -20 to 150°C and 20 to 98%RH capabilities

· Water recirculation: Allows re-use of the treated rain water

· Water conditioning: Allows the water to be cooled (5 to 20°C) prior to spray

· High pressure spray: Adds capability to meet car wash test requirement

· Drip nozzle: Adds capability to meet drip test requirement

· Rotating table: Rotates the sample for full exposure to spray

Technical parameters:

Model NoGRT-1728-AGRT-1728-E(IEC-529)(CNS14165)
Working room(L)17281728
Inner chamber size(mm)W*H*D 1200*1200*12001200*1200*1200
Exterior chamber size(mm)W*H*D1750*1850*13001750*1850*1300
Packaging volume(CBM)5.55.5
G.W.(KGs)600600
Water TemperatureNormalNormal
Spray TypeTotal water
flow(L/min)
R11.8IP×1With in 1~1.5mm/min(In drip box)
R23.2IP×2With in 3~3.5mm/min(In drip box)
S124.5IP×3Angle±600,R:400mm,1.1L/min
S239.2IP×4Angle±1800,R:400mm,1.8L/min
Pressure of
spray nozzle
(kgf/cm2)
R10.11.Flow rate of the water=0.07L/min
2.1P×3,Radius:400mm,open holes=16,total water flow:1:1L/min.
3.1P×4,Radius:400mm,open holes=25,total water flow:1:8L/min.
*Radius: 200mm,R400mm(For 1P×3,1P×4 only)
R20.3
S11
S23
Test Specimen Frame(RPM)17RPM1RPM
Spray Nozzle Rotation Speed23RPMSwing 60° from vertical for 4 seconds at one time
Swing 180° from vertical for 12 seconds at one time
MaterialInner chamber materialSUS#304

Exterior chamber material
Other ComponentsChamber lamp.Wiper
casters with Adjusters
Chamber lamp.Wiper
casters with Adjusters
Power supplyC 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50Hz
Customized serviceWelcome to Non-standard,Specail requirements,OEM/ODM orders.
The technical information will be subjected to change without notice



IPX2A IPX2A
IPX5-6 IPX5-6
Rain Rain
Rain Rain
Rain Test Chamber Rain Test Chamber
Rain Test Chamber Rain Test Chamber
RPC RPC
RS RS


同類產品推薦


提示

×

*您想獲取產品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息: