timsTOF™ Pro 捕集離子淌度質譜
參考價 | 面議 |
- 公司名稱 布魯克(北京)科技有限公司
- 品牌
- 型號 timsTOF?Pro
- 所在地 北京市
- 廠商性質 生產廠家
- 更新時間 2017/11/30 9:47:01
- 訪問次數 1894
參考價 | 面議 |
*雙TIMS排列結合了TIMS設備中離子簇的時間聚焦,意味著PASEF提供的速度優勢同時提高了靈敏度和定量。 2. PASEF技術允許以高靈敏度以及接近*的離子利用率分析樣品,同時還可以保持前體離子和產物離子的超高質量分辨率。雙TIMS設計和PASEF技術,有助于科學家們深入研究細胞復雜的分子反應機制以及發現重要低豐度生物學蛋白。
the timsTOF™ Pro Mass Spectrometer Enables the Revolutionary PASEF Method for Next-Generation Proteomics
Unique Trapped Ion Mobility Spectrometry (TIMS) Adds New Dimension for Robust, Faster Proteome Analysis with Higher Sensitivity
Mass spectrometry (MS)-based proteomics has become a powerful technology for the identification and quantification of thousands of proteins. However, the coverage of complete proteomes is still very challenging due to the limited speed, sensitivity and resolution of current mass spectrometers.
The timsTOF Pro uses the Parallel Accumulation Serial Fragmentation (PASEF) acquisition method to provide extremely high speed and sensitivity to reach new depths in shotgun proteomics and phosphoproteomics using low sample amounts.
A near * duty cycle for high sensitivity, high speed shotgun proteomics can now be achieved with the dual TIMS technology. The novel design allows for ions to be accumulated in the front section, while ions in the rear section are simultaneously released depending on their ion mobility. This process is called Parallel Accumulation Serial Fragmentation or PASEF.
The timsTOF Pro powered by PASEF offers sequencing speed > 100 Hz without losing sensitivity by synchronizing the quadrupole isolation mass window with the elution time of the specific peptide packages from the TIMS funnel.
An open-file data format allows researchers to directly work with the raw data and use industry leading software. MaxQuant has been adapted to manage 4D features in the space spanned by retention time, ion mobility, mass, and signal intensity which benefit the identification and quantification of peptides, proteins, and posttranslational modifications. PEAKS Studio combines de novo sequencing with tradtional databbase searches and is optimized for processing timsTOF raw data.
Technical Details
Outstanding hardware performance
The second generation dual TIMS analyzer is optimized for shotgun proteomics needs. Due to its unique geometry ions are released dependent on their mobility from the second section of the TIMS analyzer while the further incoming ions can be accumulated in parallel in the first part of the TIMS analyzer. With the parallel accumulation technology a duty cycle up to * can be achieved resulting in no ion loss.
In the timsTOF Pro an advanced segmented quadrupole mass filter is used for high ion transmission and isolation efficiency. The quadrupole mass position is synchronized with the elution times of the specific ions from the TIMS analyzer. Due to its ultra-high mass position switching time (< 1 ms) it enables the best performance for the PASEF method.
TIMS
Trapped Ion Mobility Spectrometry (TIMS) is first and foremost a separation technique in gas phase, which resolves sample complexity with an added dimension of separation in addition to HPLC and mass spectrometry, increasing peak capacity and confidence in compound characterization.
PASEF
With speed in mind, Bruker experts redesigned MS/MS technology to meet the requirements of shotgun proteomics. Peptide ions are separated using trapped ion mobility spectrometry, eluted (~ 100 ms) and detected in the QTOF, generating the TIMS MS heat map (A). In the PASEF method (B) the same TIMS separation is used with the quadrupole isolating a certain ion species during its elution and immediay shifting to the next precursor. Parent and fragment spectra are aligned by mobility values. With the Parallel Accumulation Serial Fragmentation (PASEF) Technology >100 Hz sequencing speed can be achieved. With the PASEF method the MS/MS spectra quality of the low abundant peptides can be increased by selecting them several times.
*您想獲取產品的資料:
個人信息: